Skip to main content
Workforce LibreTexts

3.4.1: Central Air Conditioning Systems

  • Page ID
    41191
  • \( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)

    \( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)

    \( \newcommand{\dsum}{\displaystyle\sum\limits} \)

    \( \newcommand{\dint}{\displaystyle\int\limits} \)

    \( \newcommand{\dlim}{\displaystyle\lim\limits} \)

    \( \newcommand{\id}{\mathrm{id}}\) \( \newcommand{\Span}{\mathrm{span}}\)

    ( \newcommand{\kernel}{\mathrm{null}\,}\) \( \newcommand{\range}{\mathrm{range}\,}\)

    \( \newcommand{\RealPart}{\mathrm{Re}}\) \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)

    \( \newcommand{\Argument}{\mathrm{Arg}}\) \( \newcommand{\norm}[1]{\| #1 \|}\)

    \( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)

    \( \newcommand{\Span}{\mathrm{span}}\)

    \( \newcommand{\id}{\mathrm{id}}\)

    \( \newcommand{\Span}{\mathrm{span}}\)

    \( \newcommand{\kernel}{\mathrm{null}\,}\)

    \( \newcommand{\range}{\mathrm{range}\,}\)

    \( \newcommand{\RealPart}{\mathrm{Re}}\)

    \( \newcommand{\ImaginaryPart}{\mathrm{Im}}\)

    \( \newcommand{\Argument}{\mathrm{Arg}}\)

    \( \newcommand{\norm}[1]{\| #1 \|}\)

    \( \newcommand{\inner}[2]{\langle #1, #2 \rangle}\)

    \( \newcommand{\Span}{\mathrm{span}}\) \( \newcommand{\AA}{\unicode[.8,0]{x212B}}\)

    \( \newcommand{\vectorA}[1]{\vec{#1}}      % arrow\)

    \( \newcommand{\vectorAt}[1]{\vec{\text{#1}}}      % arrow\)

    \( \newcommand{\vectorB}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)

    \( \newcommand{\vectorC}[1]{\textbf{#1}} \)

    \( \newcommand{\vectorD}[1]{\overrightarrow{#1}} \)

    \( \newcommand{\vectorDt}[1]{\overrightarrow{\text{#1}}} \)

    \( \newcommand{\vectE}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash{\mathbf {#1}}}} \)

    \( \newcommand{\vecs}[1]{\overset { \scriptstyle \rightharpoonup} {\mathbf{#1}} } \)

    \( \newcommand{\vecd}[1]{\overset{-\!-\!\rightharpoonup}{\vphantom{a}\smash {#1}}} \)

    \(\newcommand{\avec}{\mathbf a}\) \(\newcommand{\bvec}{\mathbf b}\) \(\newcommand{\cvec}{\mathbf c}\) \(\newcommand{\dvec}{\mathbf d}\) \(\newcommand{\dtil}{\widetilde{\mathbf d}}\) \(\newcommand{\evec}{\mathbf e}\) \(\newcommand{\fvec}{\mathbf f}\) \(\newcommand{\nvec}{\mathbf n}\) \(\newcommand{\pvec}{\mathbf p}\) \(\newcommand{\qvec}{\mathbf q}\) \(\newcommand{\svec}{\mathbf s}\) \(\newcommand{\tvec}{\mathbf t}\) \(\newcommand{\uvec}{\mathbf u}\) \(\newcommand{\vvec}{\mathbf v}\) \(\newcommand{\wvec}{\mathbf w}\) \(\newcommand{\xvec}{\mathbf x}\) \(\newcommand{\yvec}{\mathbf y}\) \(\newcommand{\zvec}{\mathbf z}\) \(\newcommand{\rvec}{\mathbf r}\) \(\newcommand{\mvec}{\mathbf m}\) \(\newcommand{\zerovec}{\mathbf 0}\) \(\newcommand{\onevec}{\mathbf 1}\) \(\newcommand{\real}{\mathbb R}\) \(\newcommand{\twovec}[2]{\left[\begin{array}{r}#1 \\ #2 \end{array}\right]}\) \(\newcommand{\ctwovec}[2]{\left[\begin{array}{c}#1 \\ #2 \end{array}\right]}\) \(\newcommand{\threevec}[3]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \end{array}\right]}\) \(\newcommand{\cthreevec}[3]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \end{array}\right]}\) \(\newcommand{\fourvec}[4]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \\ #4 \end{array}\right]}\) \(\newcommand{\cfourvec}[4]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \\ #4 \end{array}\right]}\) \(\newcommand{\fivevec}[5]{\left[\begin{array}{r}#1 \\ #2 \\ #3 \\ #4 \\ #5 \\ \end{array}\right]}\) \(\newcommand{\cfivevec}[5]{\left[\begin{array}{c}#1 \\ #2 \\ #3 \\ #4 \\ #5 \\ \end{array}\right]}\) \(\newcommand{\mattwo}[4]{\left[\begin{array}{rr}#1 \amp #2 \\ #3 \amp #4 \\ \end{array}\right]}\) \(\newcommand{\laspan}[1]{\text{Span}\{#1\}}\) \(\newcommand{\bcal}{\cal B}\) \(\newcommand{\ccal}{\cal C}\) \(\newcommand{\scal}{\cal S}\) \(\newcommand{\wcal}{\cal W}\) \(\newcommand{\ecal}{\cal E}\) \(\newcommand{\coords}[2]{\left\{#1\right\}_{#2}}\) \(\newcommand{\gray}[1]{\color{gray}{#1}}\) \(\newcommand{\lgray}[1]{\color{lightgray}{#1}}\) \(\newcommand{\rank}{\operatorname{rank}}\) \(\newcommand{\row}{\text{Row}}\) \(\newcommand{\col}{\text{Col}}\) \(\renewcommand{\row}{\text{Row}}\) \(\newcommand{\nul}{\text{Nul}}\) \(\newcommand{\var}{\text{Var}}\) \(\newcommand{\corr}{\text{corr}}\) \(\newcommand{\len}[1]{\left|#1\right|}\) \(\newcommand{\bbar}{\overline{\bvec}}\) \(\newcommand{\bhat}{\widehat{\bvec}}\) \(\newcommand{\bperp}{\bvec^\perp}\) \(\newcommand{\xhat}{\widehat{\xvec}}\) \(\newcommand{\vhat}{\widehat{\vvec}}\) \(\newcommand{\uhat}{\widehat{\uvec}}\) \(\newcommand{\what}{\widehat{\wvec}}\) \(\newcommand{\Sighat}{\widehat{\Sigma}}\) \(\newcommand{\lt}{<}\) \(\newcommand{\gt}{>}\) \(\newcommand{\amp}{&}\) \(\definecolor{fillinmathshade}{gray}{0.9}\)

     

    Central Air Conditioning Systems: How They Cool Entire Buildings

         Central air conditioning systems are designed to maintain consistent temperatures throughout an entire building, whether it’s a residential home, office, school, or large commercial space. Unlike localized cooling systems, which cool only a single room or area, central air conditioning operates through a centralized unit that conditions air before distributing it evenly via a network of ducts. This type of system ensures uniform cooling, prevents hot and cold spots, and improves overall indoor air quality.

         At the heart of a central AC system is the air handler, which contains critical components such as the evaporator coil, blower fan, and filtration system. When warm indoor air is pulled into the system through return ducts, it passes over the evaporator coil, where the refrigerant absorbs heat from the air. This now-cooled air is then pushed back into the ductwork by the blower fan, ensuring that every room in the building receives the desired temperature.

         Meanwhile, the absorbed heat doesn’t just disappear—it is transferred to the refrigerant and sent to the outdoor condenser unit, where it is released into the outside air. The compressor plays a crucial role here, as it pressurizes the refrigerant to facilitate efficient heat exchange. Once the refrigerant releases the heat, it cycles back to the evaporator to absorb more heat, continuing the cooling process in a closed loop.


     

    Ductwork and Air Handling in Centralized Cooling

         The efficiency of a central air conditioning system depends heavily on the ductwork, which serves as the highway for conditioned air to travel throughout the building. Proper duct design, sizing, and insulation are essential for minimizing energy loss and ensuring consistent airflow. Poorly designed or leaky ductwork can lead to uneven cooling, wasted energy, and increased strain on the AC unit, causing higher utility bills and potential system failure over time.

    Ductwork Components and Their Functions:

    • Supply Ducts: These carry the cooled air from the air handler to various rooms. They must be properly sized to prevent excessive airflow resistance and maintain consistent temperatures.
    • Return Ducts: These pull warm air from the rooms back to the air handler, ensuring a continuous cycle of cooling. An inadequate return system can cause poor airflow and inefficient cooling.
    • Dampers: These are used in zoned cooling systems, allowing for control over airflow to different parts of the building. This is especially useful in large buildings with varying cooling needs.
    • Duct Insulation: Without proper insulation, ductwork exposed to unconditioned spaces (like attics or crawl spaces) can lose cooled air, reducing system efficiency and forcing the AC unit to work harder.

     

    How Air Handling Ensures Comfort and Efficiency

         The air handler is the core component that regulates airflow and air distribution. Inside the air handler, the blower motor forces air through the duct system, ensuring even temperature distribution. The type of blower used can affect energy efficiency:

    • Single-speed blowers operate at full capacity whenever the AC is running, which can lead to higher energy costs.
    • Variable-speed blowers adjust airflow based on demand, improving efficiency and providing more precise temperature control.

         Air filtration is another crucial aspect of air handling. The air handler includes filters that trap dust, pollen, and other airborne particles before circulating the air through the building. Regular filter changes improve indoor air quality and prevent debris buildup that could restrict airflow and reduce cooling performance.

     

    Common Issues and Maintenance for Central AC Systems

         Because central air conditioning systems rely on multiple interconnected components, routine maintenance is critical to prevent breakdowns and ensure efficiency. Some common issues include:

    • Blocked or Dirty Air Filters: A clogged filter reduces airflow, forcing the system to work harder and increasing energy consumption.
    • Duct Leaks: Even small leaks in ductwork can result in significant energy loss and uneven cooling.
    • Improper Duct Sizing: Undersized ducts restrict airflow, while oversized ducts reduce air velocity, both leading to inefficient cooling.
    • Blower Motor Malfunctions: If the blower fan isn’t working properly, conditioned air won’t reach all areas of the building, causing hot spots.

         Regular maintenance involves inspecting and cleaning ductwork, replacing filters, checking refrigerant levels, and ensuring all mechanical components are operating efficiently. Properly maintained central air conditioning systems provide long-lasting, energy-efficient cooling that keeps entire buildings comfortable even during the hottest months.


    This page titled 3.4.1: Central Air Conditioning Systems is shared under a CC BY-NC 4.0 license and was authored, remixed, and/or curated by Richard Valenzuela.